|  contact

Quartz burner SSQ 141/18 WS 3.2 - 6.2

Machine burners, surface mix

WS - hydrogen, oxygen


with radially adjusted burner heads made of quartz
glass. For hydrogen and oxygen, alternatively with
3,4,5 or 6 burner heads. With 5 burner heads and
more with medial supply on both sides

Construction:
Burner heads made of quartz glass, they could be
swivelled via ball joint, base made of stainless steel
with inner thread 1/4“, feeding pipes alternatively to
1/4“ inner thread, to needle valves with hose glands
or to swivel-screws (see below mentioned).

Advantages:
· no metallic abrasion
· low noise working method
· concentrated, homogeneous flame formation
· no-water cooling required even during continuous
  operation

For the acceptance of burners we recommend the
burner holders according to our cat.-no. 141/18/35 -
141/18/37 (depending on centre height of the
machine).

Picture shows 141/18/6.2

Item number: VB1-00708

Machine burner with 3 burner heads, with swivel screws, with clamping ring connection for tube dia. 10 mm

Item number: SSQ 141/18/4.2

Machine burner with 3 burner heads, with swivel screws, with clamping ring connection for tube dia. 10 mm

Item number: SSQ 141/18/5.2

Machine burner with 5 burner heads, with swivel screws on both sides, with clamping ring connection for tube dia. 10 mm

Item number: SSQ 141/18/6.2

Machine burner with 6 burner heads, with swivel screws on both sides, with clamping ring connection for tube dia. 10 mm

Technical Details

Downloads

SSQ 141/18/3.2

Capacity22.5 KW
max O2 flow rate3.6 m3/h
max. gas flow rate7.5 m3/h
Pre-pressure oxygen1.5 - 2 bar
Pre-pressure gas1 - 1.5 bar
Gland dia. for oxygen9 mm
Gland dia. for gas11 mm
For tube dia. approx.25 mm
Number of burner heads3

SSQ 141/18/4.2

Capacity30 KW
max O2 flow rate4.8 m3/h
max. gas flow rate10 m3/h
Pre-pressure oxygen1.5 - 2 bar
Pre-pressure gas1 - 1.5 bar
Gland dia. for oxygen9 mm
Gland dia. for gas11 mm
For tube dia. approx.25 mm
Number of burner heads4

SSQ 141/18/5.2

Capacity37.5 KW
max O2 flow rate6 m3/h
max. gas flow rate12.5 m3/h
Pre-pressure oxygen1.5 - 2 bar
Pre-pressure gas1 - 1.5 bar
Gland dia. for oxygen9 mm
Gland dia. for gas11 mm
For tube dia. approx.30 mm
Number of burner heads5

SSQ 141/18/6.2

Capacity45 KW
max O2 flow rate7.2 m3/h
max. gas flow rate15 m3/h
Pre-pressure oxygen1.5 - 2 bar
Pre-pressure gas1 - 1.5 bar
Gland dia. for oxygen9 mm
Gland dia. for gas11 mm
For tube dia. approx.35 mm
Number of burner heads6